RELDC 220V
Technical Data
- Nominal input voltage U<sub>N</sub>: DC 220 V
- Input voltage range: -20 +10 %
- Nominal input current at U<sub>N</sub>: 4.1 mA
- Number of changeover/switchover contacts: 4
- Contact material (relay): AgCe
- Limiting continuous current: 5 A
- Max. make current (resistive): (AC) 15 A / 4 s
- Max. switching voltage: AC 250 V
- Max. switching power (resistive): AC 1250 VA; DC see load limit curve
- Recommended minimum load: 12 V / 100 mA
- Pull-in time (typ.): 25 ms
- Drop-out time (typ.): 25 ms
- Bounce time (typ): 4 ms
- Electrical life (N.O.; resistive load; 23 C): 100 x 10<sup>3 </sup>switching operations
- Mechanical life: 20 x 10<sup>6</sup> switching operations
- Status indication: Mechanical
- Rated voltage: 250 V
- Rated impulse voltage: 2.5 kV
- Pollution degree: 2
- Dielectric strength, control/load circuit (AC, 1 min): 1.5 kVrms
- Dielectric strength open contact (AC, 1 min): 1 kVrms
- Dielectric strength, load/load circuit (AC, 1 min): 1.5 kVrms
- Protection class: IP20
Connection Data
- Connection technology: Push-in CAGE CLAMP<sup></sup>
- Solid conductor: 0.34 1.5 mm / 22 16 AWG
- Fine-stranded conductor: 0.34 1.5 mm / 22 16 AWG
- Strip length: 9 10 mm / 0.35 0.39 inch
- Note (conductor cross-section): 2 x 0.34 2 x 1.5 mm / 1 x 2.5 mm / 2 x 22 2 x 16 AWG
Geometrical Data
- Width: 31 mm / 1.22 inch
- Height from upper-edge of DIN-35 rail: 73 mm / 2.874 inch
- Depth: 97 mm / 3.819 inch
Mechanical Data
- Type of mounting: DIN-35 rail
Material Data
- Fire load: 0.000 MJ
- Weight: 93.400 g
Environmental Requirements
- Surrounding air (operating) temperature at U<sub>N</sub>: -25 70 C
- Surrounding air (storage) temperature: -40 80 C
- Processing temperature: -25 +50 C
Standards and specifications
- Standards/specifications: EN 61010-2-201; EN 61810-1; EN 61373; UL 508 (max. 50 C)
Elementary relay
- WAGO elementary relay: 858-166
Commercial data
- Packaging type: BOX
- Country of origin: DE
- GTIN: 4055143568203
- Customs Tariff No.: 85364900990
The WAGO 858 series plug-in relay assembly features a socket base, manual operation, and a red LED indicator. It is a 4-pole (4P) relay with a control voltage range of 176-242Vdc (nominal 220Vdc) and 4C/O (4 Pole Double Throw) contacts. The electromechanical design supports a rated current of 5A continuous, 1A at 240Vac (AC-15), and 2A at 24Vdc (DC-13). It includes Push-in CAGE CLAMP connections and is designed for DIN-35 rail mounting with a 31mm width. The relay has an IP20 protection rating and uses Silver-Cerium (AgCe) contacts, equivalent to model 858308.
- bounce time typ:
- 4 ms
- connection technology:
- Push-in CAGE CLAMP
- contact material relay:
- AgCe
- country of origin sales organisation germany:
- DE
- depth from upper edge of din rail:
- 73 mm / 2.874 inch
- dielectric strength control load circuit ac 1 min:
- 1.5 kVrms
- dielectric strength load load circuit ac 1 min:
- 1.5 kVrms
- dielectric strength open contact ac 1 min:
- 1 kVrms
- drop out time typ:
- 25 ms
- electrical life no resistive load 23 c:
- 100 x 103 switching operations
- fine stranded conductor:
- 0.34 1.5 mm / 22 16 AWG
- fire load:
- 1.226 MJ
- height:
- 97 mm / 3.819 inch
- input voltage range:
- -20 +10 %
- inrush current resistive max:
- (AC) 15 A / 4 s
- insulation type adjacent devices:
- Reinforced insulation (safe isolation)
- insulation type control load circuit:
- Basic insulation
- insulation type load load circuit:
- Basic insulation
- limiting continuous current:
- 0.208333333333333
- mechanical life:
- 20 x 106 switching operations
- mounting position:
- Horizontal (standing/lying): vertical
- mounting type:
- DIN-35 rail
- nominal input current at un:
- 4.1 mA
- nominal input voltage un:
- DC 220 V
- note conductor cross section:
- 2 x 0.34 2 x 1.5 mm / 1 x 2.5 mm / 2 x 22 2 x 16 AWG
- number of changeover switchover contacts:
- 4
- operating altitude max:
- 2000 m
- packaging type:
- Box
- pollution degree:
- 2
- processing temperature:
- -25 +50 C
- protection type:
- IP20
- pull in time typ:
- 25 ms
- rated surge voltage:
- 2.5 kV
- rated voltage:
- 300 V
- recommended minimum load:
- 12 V / 100 mA
- relative humidity:
- 5 85 %
- solid conductor:
- 0.34 1.5 mm / 22 16 AWG
- standards specifications:
- EN 61010-2-201 || EN 61810-1 || EN 61373 || UL 508 (max. 50 C)
- status indicator:
- Red LED || Mechanical
- strip length:
- 9 10 mm / 0.35 0.39 inch
- surrounding air temperature operation at un:
- -25 70 C
- surrounding air temperature storage:
- -40 70 C
- switching capacity:
- AC-15: 1 A / AC 240 V: DC-13: 2 A / DC 24 V
- switching power resistive max:
- AC 1250 VA: DC (see load limit curve)
- switching voltage max:
- AC 250 V
- wago basic relay:
- 858-166
- weight:
- 93.400 g
- width:
- 31 mm / 1.22 inch