- achievable safety classes:
- SIL 3: Category 4, PLe (two-channel): SIL 2: Category 2: PLd (one-channel)
- actuator connection:
- 4 x (fail-safe output with test pulse)
- ambient temperature operation:
- 0 ¦ +55 °C
- capacitive load for each channel:
- O1 ¦ O4
- configuration options:
- PROFIsafe address adjustable via DIP switch or engineering software
- conformity marking:
- CE
- connection technology inputs outputs:
- 16 x CAGE CLAMP®
- connection type 1:
- Inputs/outputs
- COUNTRY OF ORIGIN VKORG GERMANY:
- DE
- CURRENT CARRYING CAPACITY POWER JUMPER CONTACTS:
- 0.416666666666667
- CURRENT CONSUMPTION 5 V SYSTEM SUPPLY:
- 120 mA
- CURRENT CONSUMPTION FIELD SUPPLY MODULE WITH NO EXTERNAL LOAD:
- 35 mA
- CUSTOMS TARIFF NUMBER VKORG GERMANY:
- 85389099990
- DEPTH:
- 67.8 mm / 2.669 inches
- DEPTH FROM UPPER EDGE OF DIN RAIL:
- 60.6 mm / 2.386 inches
- EMC EMISSION OF INTERFERENCE:
- Per EN 61000-6-3, -4
- EMC IMMUNITY TO INTERFERENCE:
- Per EN 61000-6-2, marine applications, EN 61000-6-7 (FS)
- EXPOSURE TO POLLUTANTS:
- Per IEC 60068-2-42 and IEC 60068-2-43
- FINE STRANDED CONDUCTOR:
- 0.08 ¦ 2.5 mm² / 28 ¦ 14 AWG
- FIRE LOAD:
- 1.931 MJ
- HEIGHT:
- 100 mm / 3.937 inches
- HOUSING MATERIAL:
- Polycarbonate
- INDICATORS:
- LED (A-D) green/red: Status/Error I1 ¦ I4
- INPUT CHARACTERISTIC:
- Clock sensitive || Type 1 per IEC 61131
- INPUT CURRENT PER CHANNEL FOR SIGNAL 1 TYP:
- 3.0 mA
- INTERFACE TYPES ACCORDING TO ZVEI INPUTS:
- Drain
- INTERFACE TYPES ACCORDING TO ZVEI OUTPUTS:
- Source
- LOAD TYPE OF SWITCHING FREQUENCY:
- Resistive load
- MEASUREMENT ERROR DEVIATION MAX FROM THE UPPER RANGE VALUE:
- MEASUREMENT ERROR DEVIATION MAX OF THE UPPER RANGE VALUE 2=
- MISMATING PROTECTION:
- MOUNTING NOTE=
- MOUNTING POSITION:
- Horizontal (standing/lying)
- MOUNTING TYPE:
- DIN-35 rail
- NUMBER OF DIGITAL OUTPUTS:
- 4
- NUMBER OF INCOMING POWER JUMPER CONTACTS:
- 2
- NUMBER OF OUTGOING POWER JUMPER CONTACTS:
- 2
- OPERATING ALTITUDE:
- 0 ¦ 2000 m / 0 ¦ 6562 ft
- OUTPUT CIRCUIT DESIGN:
- Short-circuit-protected
- OUTPUT CURRENT MODULE:
- 0.333333333333333
- OUTPUT CURRENT PER CHANNEL:
- 0.0833333333333333
- PERMISSIBLE H2S CONTAMINANT CONCENTRATION AT A RELATIVE HUMIDITY 75:
- 10 ppm
- PERMISSIBLE SO2 CONTAMINANT CONCENTRATION AT A RELATIVE HUMIDITY 75:
- 25 ppm
- PLUGGABLE CONNECTOR:
- Fixed
- POLLUTION DEGREE 5:
- 2 per IEC 61131-2
- PRODUCT GROUP CODE:
- 15
- PROTECTION TYPE:
- IP20
- RELATIVE HUMIDITY WITHOUT CONDENSATION:
- 0.95
- SAFETY STANDARDS:
- IEC 61508-1 ¦ -7
- SENSOR CONNECTION:
- 4 x (Fail-safe input with test pulse)
- SHOCK RESISTANCE:
- 15g per IEC 60068-2-27
- SIGNAL FREQUENCY MAX:
- 50 Hz
- SIGNAL TYPE:
- Voltage
- SIGNAL TYPE VOLTAGE:
- 24 VDC
- SOLID CONDUCTOR:
- 0.08 ¦ 2.5 mm² / 28 ¦ 14 AWG
- STRIP LENGTH:
- 8 ¦ 9 mm / 0.31 ¦ 0.35 inches
- SUPPLY VOLTAGE FIELD:
- 24 VSELV/PELV DC (-25 ¦ +20 %)
- SUPPLY VOLTAGE SYSTEM:
- 5 VDC
- SURROUNDING AIR TEMPERATURE STORAGE:
- -25 ¦ +85 °C
- SWITCHING FREQUENCY MAX:
- 50 Hz
- SWITCHING FREQUENCY MAX 2:
- 0.1 Hz
- TEST PULSE DURATION MAX:
- 500 ms
- TEST PULSE DURATION MIN:
- 0 ms
- TOTAL NUMBER OF CHANNELS MODULE:
- 8
- VIBRATION RESISTANCE:
- 4g per IEC 60068-2-6
- WEIGHT:
- 101.647 g
- WIDTH: