- configurable functions do:
- Disabled || US/GND switching || Threshold value switch || Frequency generator || Pulse output (S0 interface)
- configurable rise fall delay time do:
- 0 60 s (via software)
- configurable rise fall delay time relay:
- 0 60 s (via software)
- configuration options:
- WAGO Interface Configuration Software || WAGO Configuration Display
- conformity marking:
- CE
- connection technology:
- Push-in CAGE CLAMP
- continuous current do max:
- 100 mA (no internal restriction)
- country of origin sales organisation germany:
- DE
- depth from upper edge of din rail:
- 107 mm / 4.213 inch
- dielectric strength open contact ac 1 min:
- 1 kVrms
- emc emission of interference:
- EN 61000-6-3: EN 61326-2-3
- emc immunity to interference:
- EN 61000-6-2: EN 61326-2-3
- fine stranded conductor:
- 0.2 2.5 mm / 24 12 AWG
- fire load:
- 1.796 MJ
- frequency range:
- 15 400 Hz
- height:
- 110 mm / 4.331 inch
- input current max:
- 1.2 IN (¤ 60 C): 1 IN (60 70 C)
- input signal current:
- AC/DC 1 A (IN 3.1): AC/DC 5 A (IN 3.2) : AC/DC 8 A (IN 3.3)
- input signal type:
- Voltage || Current
- input signal voltage:
- AC/DC 500 V (IN 2.1: per EN 61010-1): AC/DC 300 V (IN 2.1: per UL 61010-1): AC/DC 250 V (IN 2.2) : AC/DC 30 V (IN 2.3)
- input voltage max:
- 1.2 UN
- insulation type input in 2 1 relay output:
- Reinforced insulation
- insulation type input supply analog output relay output:
- Double insulation (impedance and basic insulation) || Requirement: The N (GND 1) input is dangerous when active!
- limit frequency:
- 2 kHz
- limiting continuous current relay module assembly:
- 6 A (¤ 60 C): 3 A (60 70 C)
- line to neutral conductor voltage ac max:
- 300 V
- load impedance current output:
- ¤ 600
- load impedance voltage output:
- 2 k
- measured variables calculated:
- Active power || Apparent power || Reactive power || Mains frequency || Phase angle
- measurement method:
- True RMS measurement (TRMS)
- mounting type:
- DIN-35 rail
- nominal supply voltage us:
- DC 24 V (SELV)
- note:
- This product is supplied with 24 VDC, which can be commoned using lateral push-in type jumper bars: (6.1) US+ (BR) and (6.2) GND 2 (BR). With this variant, it is necessary to ensure that the maximum permissible total current of 6 A is not exceeded.Ad
- number of changeover switchover contacts:
- 1
- number of switching thresholds do:
- 2 (max.)
- number of switching thresholds relay:
- 1 or 2 (adjustable)
- operating altitude max:
- 2000 m
- output signal current:
- 24 mA (SELV)
- output signal type:
- Current || Voltage
- output signal voltage:
- 12 V (SELV)
- overvoltage category:
- III
- packaging type:
- Bag
- pollution degree:
- 2
- power consumption at nominal supply voltage:
- ¤ 70 mA (+ IDO)
- power supply type:
- 24 VDC
- relative humidity:
- 5 85 % (non-condensing)
- resolution current:
- 1 mA (for all measurement ranges)
- resolution voltage:
- 50 mV (IN 2.1) || 30 mV (IN 2.2) || 5 mV (IN 2.3)
- response threshold current:
- 1.5 mA AC / 7.5 mA DC (IN 3.1) || 3 mA AC / 10 mA DC (IN 3.2) || 7.5 mA AC / 12 mA DC (IN 3.3)
- response threshold voltage:
- 500 mVAC / 600 mVDC (IN 2.1) || 50 mVAC / 500 mVDC (IN 2.2) || 20 mVAC / 100 mVDC (IN 2.3)
- setting range frequency generator:
- 0.3 100 Hz
- setting range pulse output:
- 1000 1 Impulse/kW
- software filter adjustable:
- Filter level: 1 30
- solid conductor:
- 0.2 2.5 mm / 24 12 AWG
- standards specifications:
- EN 61010-1 || UL 61010-1 || UL 61010-2-201
- step response max:
- 350 ms (for default settings)
- strip length:
- 9 10 mm / 0.35 0.39 inch
- supply voltage range:
- 30 %
- surrounding air temperature operation:
- -40 70 C
- surrounding air temperature storage:
- -40 85 C
- switching voltage do max:
- Supply voltage (applied): 0.3 V
- switching voltage max:
- AC 250 V
- temperature range of connecting cable per ul 61010 2 201 min:
- 95 C
- temperature range of the connecting cable according to en 61010 2 201:
- (Tsurrounding air + 25 K)
- test voltage input in 2 1 relay output per en 61010 1:
- 5.4 kVAC : 50 Hz: 5 s || 3.6 kVAC: 50 Hz: 1 min
- test voltage input in 2 1 relay output per ul 61010 1:
- 3.51 kVAC: 60 Hz: 1 min
- test voltage supply analog output:
- 3.6 kVAC: 50 60 Hz: 1 min
- transmission error max:
- ¤ 0.5 % for current and voltage (of the full scale value)
- wago connector:
- picoMAX 5.0
- weight:
- 149.000 g
- width:
- 22.5 mm / 0.886 inch