4-conductor fuse terminal block; with pivoting fuse holder; and end plate; for 5 x 20 mm miniature metric fuse; with push-button; without blown fuse indication; for DIN-rail 35 x 15 and 35 x 7.5; 2.5 mm²; Push-in CAGE CLAMP; 2,50 mm²; orange.
The WAGO 2202 TOPJOB S series is an orange feed-through terminal block with a single deck and a fused-disconnect lever type for 5x20mm fuses. It features a built-in end plate, side and center marking slots, and accommodates one feed-through pole with four push-in wire connections (2+2). It supports a nominal cross-section of 2.5mm² and wire sizes from 0.25mm² to 4mm² (#22AWG to #12AWG). Rated for a current of 6.3A, it uses Push-in CAGE CLAMP spring connections and mounts on a DIN-35 rail with a width of 6.2mm, equivalent to model 22021812.
- actuation type:
- Push-in || Push-button
- approvals per:
- UL 1059
- color:
- Orange
- connectable conductor materials:
- Copper
- connection technology:
- Push-in CAGE CLAMP®
- CONTINUOUS OPERATING TEMPERATURE:
- -60 ¢¦ +105 °C
- COUNTRY OF ORIGIN VKORG GERMANY:
- DE
- CUSTOMS TARIFF NUMBER VKORG GERMANY:
- 85369095000
- DEPTH FROM UPPER EDGE OF DIN RAIL:
- 57.6 mm / 2.268 inches
- FINE STRANDED CONDUCTOR:
- 0.25 ¢¦ 4 mm² / 22 ¢¦ 12 AWG
- FINE STRANDED CONDUCTOR WITH FERRULE PUSH IN TERMINATION:
- 1 ¢¦ 2.5 mm² / 18 ¢¦ 14 AWG
- FINE STRANDED CONDUCTOR WITH INSULATED FERRULE:
- 0.25 ¢¦ 2.5 mm² / 22 ¢¦ 14 AWG
- FIRE LOAD:
- 0.076 MJ
- FLAMMABILITY CLASS PER UL94:
- V0
- HEIGHT:
- 87.5 mm / 3.445 inches
- INSULATION MATERIAL:
- Polyamide (PA66)
- LEGEND RATINGS:
- (III / 3) ¢ Overvoltage category III / Pollution degree 3
- MARKING LEVEL:
- Center/side marking
- MATERIAL GROUP:
- I
- MEASUREMENT ERROR DEVIATION MAX FROM THE UPPER RANGE VALUE:
- MEASUREMENT ERROR DEVIATION MAX OF THE UPPER RANGE VALUE 2=
- MISMATING PROTECTION:
- MOUNTING NOTE=
- MOUNTING TYPE:
- DIN-35 rail
- NOMINAL CROSS SECTION:
- 2.5 mm²
- NOMINAL VOLTAGE III 3:
- 250 V
- NOTE CONDUCTOR CROSS SECTION:
- Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
- NOTE MATERIAL DATA:
- Information on material data can be found here
- OPERATION STATUS INDICATOR:
- None
- POWER LOSS MAX PL MAX NOTE:
- When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN 60947-7-3/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked
- POWER LOSS PL 3 MAX:
- 1.6 W
- POWER LOSS PL MAX OVERLOAD AND SHORT CIRCUIT PROTECTION GROUP ARRANGEMENT:
- 1.6 W
- POWER LOSS PL MAX OVERLOAD AND SHORT CIRCUIT PROTECTION INDIVIDUAL ARRANGEMENT:
- 1.6 W
- POWER LOSS PL MAX SHORT CIRCUIT PROTECTION GROUP ARRANGEMENT:
- 1.6 W
- PROCESSING TEMPERATURE:
- -35 ¢¦ +85 °C
- PRODUCT GROUP CODE:
- 36
- RATED CURRENT:
- 6.3 A
- RATED CURRENT CSA USE GROUP B:
- 0.416666666666667
- RATED CURRENT CSA USE GROUP C:
- 0.416666666666667
- RATED CURRENT CSA USE GROUP D:
- 0.416666666666667
- RATED CURRENT UL USE GROUP B:
- 0.416666666666667
- RATED CURRENT UL USE GROUP C:
- 0.416666666666667
- RATED IMPULSE VOLTAGE III 3:
- 6 kV
- RATED VOLTAGE CSA USE GROUP B:
- 250 V
- RATED VOLTAGE CSA USE GROUP C:
- 250 V
- RATED VOLTAGE CSA USE GROUP D:
- 250 V
- RATED VOLTAGE EN EX E II:
- 275 V
- RATED VOLTAGE UL USE GROUP B:
- 250 V
- RATED VOLTAGE UL USE GROUP C:
- 250 V
- RATED VOLTAGE UL USE GROUP D:
- 250 V
- RATINGS NOTE:
- Electrical ratings are given by the fuse.
- RATINGS PER:
- IEC/EN 60947-7-3
- REFERENCE HAZARDOUS AREAS:
- See Downloads ¢ Documentation ¢ Additional Information: Technical Section
- SOLID CONDUCTOR:
- 0.25 ¢¦ 4 mm² / 22 ¢¦ 12 AWG
- SOLID CONDUCTOR PUSH IN TERMINATION:
- 0.75 ¢¦ 4 mm² / 18 ¢¦ 12 AWG
- STRIP LENGTH:
- 10 ¢¦ 12 mm / 0.39 ¢¦ 0.47 inches
- WEIGHT:
- 16.594 g
- WIDTH:
- 6.2 mm / 0.244 inches
- WIRING DIRECTION:
- Front-entry wiring