Schneider Electric LC1K090087M7 Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 220 to 230VAC coil
Schneider Electric
$81.00
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a 220V 50/60Hz AC coil, without built-in auxiliary contact, connection by Faston connectors. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
- Device Short Name:
- LC1K
- Mounting Support:
- rail || plate
- Range:
- TeSys
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Rohs Exemption Information:
- Yes
- Average Impedance:
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Control Circuit Type:
- AC 50/60 Hz
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Inrush Power In Va:
- 30-30 VA (at 20°C)
- Hold-In Power Consumption In Va:
- 4.5-4.5 VA (at 20°C)
- Height:
- 58 mm
- Associated Fuse Rating:
- 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
- Overvoltage Category:
- III
- Pole Contact Composition:
- 2 NO + 2 NC
- Mechanical Robustness:
- shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
- Warranty:
- 18 months
- Irms Rated Making Capacity:
- 110 A AC for power circuit conforming to IEC 60947
- Ip Degree Of Protection:
- IP2X VDE 0106
- Mercury Free:
- Yes
- Eu Rohs Directive:
- Compliant
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Heat Dissipation:
- 1.3-1.3 W
- Circularity Profile:
- ENVEOLI1503003EN
- Electrical Durability:
- 0.16 Mcycles 20 A AC-1 <= 690 V
- Country of Origin:
- France
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Depth:
- 57 mm
- [Ie] Rated Operational Current:
- 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
- Operating Time:
- 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing || 15...25 ms coil de-energisation and NC closing || 5...15 ms coil energisation and NC opening
- [Ui] Rated Insulation Voltage:
- power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA C22.2 No 14
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Connections - Terminals:
- Faston terminals 2 2.8 mm) || Faston terminals 1 6.35 mm)
- Flame Retardance:
- V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
- Device Application:
- control
- Signaling Circuit Frequency:
- <= 400 Hz
- Mechanical Durability:
- 10 Mcycles
- Environmental Disclosure:
- ENVPEP1503003EN
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
- Maximum Operating Rate:
- 3600 cyc/h
- Rated Breaking Capacity:
- 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
- Sustainable Packaging:
- Yes
- Ambient Air Temperature For Storage:
- -50-80°C
- Contactor Application:
- resistive load
- Poles Description:
- 4P
- Product Or Component Type:
- contactor
- [Ith] Conventional Free Air Thermal Current:
- 20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit