TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 10A/690V AC-1. It provides a 48V 50/60Hz AC coil, without built-in auxiliary contact, connection by spring terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
- Mercury Free:
- Yes
- Ambient Air Temperature For Storage:
- -50-80°C
- Poles Description:
- 4P
- Reach Free Of Svhc:
- Yes
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Pole Contact Composition:
- 2 NO + 2 NC
- Net Weight:
- 0.18 kg
- Signaling Circuit Frequency:
- <= 400 Hz
- Flame Retardance:
- V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
- Sustainable Offer Status:
- Green Premium product
- Electrical Durability:
- 0.16 Mcycles 20 A AC-1 <= 690 V
- Rated Breaking Capacity:
- 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
- Sustainable Packaging:
- Yes
- Environmental Disclosure:
- ENVPEP1503003EN
- Contactor Application:
- resistive load
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- Average Impedance:
- 3 mOhm - Ith 16 A 50 Hz for power circuit
- Product Or Component Type:
- contactor
- Circularity Profile:
- ENVEOLI1503003EN
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Control Circuit Type:
- AC 50/60 Hz
- Ip Degree Of Protection:
- IP2X VDE 0106
- Rohs Exemption Information:
- Yes
- Mechanical Robustness:
- shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
- Standards:
- EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
- Connections - Terminals:
- spring terminals 1 0.75-1.5 mm²solid || spring terminals 1 0.75-1.5 mm²flexible without cable end || spring terminals 2 0.75-1.5 mm²flexible without cable end
- Device Short Name:
- LC1K
- Irms Rated Making Capacity:
- 110 A AC for power circuit conforming to IEC 60947
- Operating Time:
- 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing || 15...25 ms coil de-energisation and NC closing || 5...15 ms coil energisation and NC opening
- Depth:
- 57 mm
- Inrush Power In Va:
- 30-30 VA (at 20°C)
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
- Range:
- TeSys
- Height:
- 58 mm
- Mechanical Durability:
- 10 Mcycles
- [Icw] Rated Short-Time Withstand Current:
- 90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Toxic Heavy Metal Free:
- Yes
- [Ith] Conventional Free Air Thermal Current:
- 16 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
- Mounting Support:
- rail || plate
- Eu Rohs Directive:
- Compliant
- Device Application:
- control
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- [Ie] Rated Operational Current:
- 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
- Country of Origin:
- France
- Control Circuit Voltage Limits:
- operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)